Cooper&Hunter
Air conditioners
Cooper&Hunter GTH48K3CI/GUHD48NM3CO
Review ratings
|
Cooper&Hunter GTH48K3CI/GUHD48NM3CO
Rating: 0
Number of votes: 0
|
|
|
Workmanship
Relevant cost
Serviceability
|
|
Tech specifications and features
General characteristics Type: floor-ceiling split system; Inverter (stepless power): yes; Maximum length communications: 50 m; The main modes: cooling / heating; Max air flow: 38.33 cubic m/min; Power in cooling mode: 14000 W; Power in heating mode: 16500 W; Power consumption for heating: 4400 W; Power consumption at cooling: 4200 W; Fresh air mode: no; Additional modes: ventilation mode (without heating and cooling), auto mode, self-diagnostics of malfunctions; Dry mode: yes; Management Remote control: yes; On/off timer: yes; Dimensions Internal block split-systems or mobile air conditioner (WxHxD): 170x70x24.5 cm; The outdoor unit of the split-system or window air conditioner (WxHxD): 108.5x136.5x42.7 cm; Total Noise level (min/max): 52 dB / 58 dB; Refrigerant type: R 410A; Phase: three-phase; Fan speed: yes, number of speeds - 3; Other features: ability to adjust the direction of the air flow, the system against the formation of ice, memory function settings; Minimum temperature for using the air conditioner in a heating mode: -15 C; Additional information: can be equipped with additional filters; wired remote control;
|
|
Product photography
Cooper&Hunter GTH48K3CI/GUHD48NM3CO pictures
More pictures
|
|
|
Popular today
| | - wall split-system
- only air cooling mode
- ventilation mode
- automatic maintenance of temperature
- optimum mode of work in the night time
- dehumidification of the air at high humidity
- control console
|
| | - wall split-system
- heating and cooling air
- ventilation mode
- automatic maintenance of temperature
- optimum mode of work in the night time
- dehumidification of the air at high humidity
- control console
|
| | - mobile monoblock
- only air cooling mode
- control console
- area conditioning 24 sq. m
|
Similar Air conditioners
|
|
Brief specs
- ducted split-system
- pressure 150 PA
- heating and cooling air
- ventilation mode
- automatic maintenance of temperature
- optimum mode of work in the night time
- dehumidification of the air at high humidity
|
|
|
Brief specs
- floor-ceiling split system
- heating and cooling air
- ventilation mode
- automatic maintenance of temperature
- optimum mode of work in the night time
- dehumidification of the air at high humidity
- control console
|
|
|
Brief specs
- wall split-system
- heating and cooling air
- ventilation mode
- automatic maintenance of temperature
- optimum mode of work in the night time
- dehumidification of the air at high humidity
- control console
|
|