Estimated price for Electrolux EACS-24HP/N3 -
825€ - 988.32€
Review ratings
|
Electrolux EACS-24HP/N3
Rating: 0
Number of votes: 0
|
|
|
Workmanship
Relevant cost
Serviceability
|
|
Tech specifications and characteristics
General characteristics Type: wall split-system; The maximum length communications: 15 m; The main modes: cooling / heating; Max air flow: 13.33 cubic m/min; Power in cooling mode: 6505 W; Power in heating mode: 6800 W; Power consumption for heating: 1885 W; Power consumption at cooling: 2025 W; Fresh air mode: no; Additional modes: ventilation mode (without cooling and heating), automatic mode, self-diagnostics of malfunctions; Dry mode: yes; Management Remote control: yes; Timer on/off: yes; Dimensions Internal block split-systems or mobile air conditioning (WxHxD): 94x29.8x20 cm; Outdoor units of split-systems and window air conditioner (WxHxD): 83x62.9x28.5 cm; Total Refrigerant type: R 410A; Phase: single-phase; The fine filters air: yes; Adjusting the fan speed: yes; Other functions and features: deodorizing filter, anion generator, the possibility of adjusting the direction of air flow, the system against ice, the resume function settings, warm start; Serviced area: 60 sq.m; Minimum temperature for the operation of the air conditioner in a heating mode: -7 ٠c;
|
|
Product photography
Electrolux EACS-24HP/N3 pictures
More pictures
|
|
|
Popular today
| | - wall split-system
- only air cooling mode
- ventilation mode
- automatic maintenance of temperature
- optimum mode of work in the night time
- dehumidification of the air at high humidity
- control console
|
| | - wall split-system
- heating and cooling air
- ventilation mode
- automatic maintenance of temperature
- optimum mode of work in the night time
- dehumidification of the air at high humidity
- control console
|
| | - mobile monoblock
- only air cooling mode
- control console
- area conditioning 24 sq. m
|
Similar Air conditioners
|
|
Brief specs
- wall split-system
- heating and cooling air
- ventilation mode
- automatic maintenance of temperature
- the optimum mode of operation at night
- the dehumidification at high humidity
- operation via
|
|
|
Brief specs
- wall split-system
- heating and cooling air
- ventilation mode
- automatic maintenance of temperature
- optimum mode of work in the night time
- dehumidification of the air at high humidity
- control console
|
|
|
Brief specs
- wall split-system
- heating and cooling air
- ventilation mode
- automatic maintenance of temperature
- optimum mode of work in the night time
- dehumidification of the air at high humidity
- control console
|
|