Haier
Air conditioners
Haier AC60FS1ERA / 1U60IS1EAB
Review ratings
|
Haier AC60FS1ERA / 1U60IS1EAB
Rating: 0
Number of votes: 0
|
|
|
Workmanship
Relevant cost
Serviceability
|
|
Technical characteristics and specifications
General characteristics Type: floor-ceiling split system; Maximum length communications: 50 m; The main modes: cooling / heating; Max air flow: 33.33 cubic m/min; Power in cooling mode: 15500 W; Power in heating mode: 16800 W; Power consumption for heating: 5230 W; Power consumption at cooling: 5130 W; Fresh air mode: no; Additional modes: ventilation mode (without heating and cooling), auto mode, self-diagnostics of malfunctions; Dry mode: yes; Management Remote control: yes; On/off timer: yes; Dimensions Internal block split-systems or mobile air conditioner (WxHxD): 158x70x24 cm; The outdoor unit of the split-system or window air conditioner (WxHxD): 94.8x125x34 cm; Total Noise level (min/max): 49 dB-53 dB; Refrigerant type: R 410A; Phase: three-phase; Fine filters air: no; Fan speed: yes, number of speeds - 3; Other features: possibility to adjust the air flow direction memory function settings; The valid range of the min. temperature for the operation of the air conditioner: from -7 up to 10 degrees With;
|
|
Product photography
Haier AC60FS1ERA / 1U60IS1EAB pictures
More pictures
|
|
|
Popular today
| | - wall split-system
- only air cooling mode
- ventilation mode
- automatic maintenance of temperature
- optimum mode of work in the night time
- dehumidification of the air at high humidity
- control console
|
| | - wall split-system
- heating and cooling air
- ventilation mode
- automatic maintenance of temperature
- optimum mode of work in the night time
- dehumidification of the air at high humidity
- control console
|
| | - mobile monoblock
- only air cooling mode
- control console
- area conditioning 24 sq. m
|
Similar Air conditioners
|
|
Brief specs
- floor-ceiling split system
- heating and cooling air
- ventilation mode
- automatic maintenance of temperature
- optimum mode of work in the night time
- dehumidification of the air at high humidity
- control console
|
|
|
Brief specs
- column split system
- heating and cooling air
- ventilation mode
- automatic maintenance of temperature
- optimum mode of work in the night time
- dehumidification of the air at high humidity
- control console
|
|
|
Brief specs
- ducted split-system
- pressure 100 PA
- heating and cooling air
- ventilation mode
- automatic maintenance of temperature
- optimum mode of work in the night time
- dehumidification of the air at high humidity
|
|