Hyundai H-ALD1-18H-UI040
Rating: 0
Number of votes: 0
|
|
|
Workmanship
Relevant cost
Serviceability
|
|
Tech characteristics and specs
General characteristics Type: duct split-system; The maximum length communications: 25 m; The main modes: cooling / heating; Max air flow: 19.5 cubic m/min; Static pressure: 100 PA; Power in cooling mode: 5280 W; Power in heating mode: 5860 W; Power consumption for heating: 2007 W; Power consumption cooling: 2037 W; Fresh air mode: yes; Additional modes: ventilation mode (without cooling and heating), automatic mode; Dry mode: yes; Management Remote control: yes; Timer on/off: yes; Dimensions Internal block split-systems or mobile air conditioning (WxHxD): 92x21x63.5 cm; Outdoor unit split-systems and window air conditioner (WxHxD): 76x59x28.5 cm; Total Noise level (min/max): 33 dB 44 dB; Refrigerant type: R 410A; Phase: single-phase; The fine filters air: no; Adjusting the fan speed: yes, number of speeds - 3; Other functions and features: generator anions, the ability to adjust the air flow direction, the system against ice, the resume function settings; Minimum temperature for the operation of the air conditioner in a heating mode: -7°;
|
|
Product photography
Hyundai H-ALD1-18H-UI040 pictures
More pictures
|
|
|
Popular today
| | - wall split-system
- only air cooling mode
- ventilation mode
- automatic maintenance of temperature
- optimum mode of work in the night time
- dehumidification of the air at high humidity
- control console
|
| | - wall split-system
- heating and cooling air
- ventilation mode
- automatic maintenance of temperature
- optimum mode of work in the night time
- dehumidification of the air at high humidity
- control console
|
| | - mobile monoblock
- only air cooling mode
- control console
- area conditioning 24 sq. m
|
Similar Air conditioners
|
|
Brief specs
- duct split-system
- pressure 100 PA
- heating and cooling air
- ventilation mode
- automatic maintenance of temperature
- the optimum mode of operation at night
- the dehumidification at high humidity
|
|
|
Brief specs
- duct split-system
- pressure 100 PA
- heating and cooling air
- ventilation mode
- automatic maintenance of temperature
- the optimum mode of operation at night
- the dehumidification at high humidity
|
|
|
Brief specs
- duct split-system
- pressure 100 PA
- heating and cooling air
- ventilation mode
- automatic maintenance of temperature
- the optimum mode of operation at night
- the dehumidification at high humidity
|
|