Lessar
Air conditioners
Lessar LS-HE24THA2 / LU-HE24UHA2
Estimated price for Lessar LS-HE24THA2 / LU-HE24UHA2 -
1836€ - 2100€
Review ratings
|
Lessar LS-HE24THA2 / LU-HE24UHA2
Rating: 0
Number of votes: 0
|
|
|
Workmanship
Relevant cost
Serviceability
|
|
Tech specs and features
General characteristics Type: floor-ceiling split system; Inverter (stepless power): yes; Maximum length communications: 25 m; The main modes: cooling / heating; Max air flow: 16.67 cubic m/min; Power in cooling mode: 7030 W; Power in heating mode: 7600 W; Power consumption for heating: 2070 W; Power consumption at cooling: 2160 W; Fresh air mode: yes; Additional modes: ventilation mode (without heating and cooling), auto mode, self-diagnostics of malfunctions; Dry mode: yes; Management Remote control: yes; On/off timer: yes; Dimensions Internal block split-systems or mobile air conditioner (WxHxD): 99x66x20.3 cm; The outdoor unit of the split-system or window air conditioner (WxHxD): 84.2x69.5x32.4 cm; Total Noise level (min/max): 40 dB / 45 dB; Refrigerant type: R 410A; Phase: single-phase; Fine filters air: no; Fan speed: yes; Other features: ability to adjust the direction of the air flow, the system against the formation of ice, memory function settings; The valid range of the min. temperature for the operation of the air conditioner: from -15 to -15;
|
|
Product photography
Lessar LS-HE24THA2 / LU-HE24UHA2 pictures
More pictures
|
|
|
Popular today
| | - wall split-system
- only air cooling mode
- ventilation mode
- automatic maintenance of temperature
- optimum mode of work in the night time
- dehumidification of the air at high humidity
- control console
|
| | - wall split-system
- heating and cooling air
- ventilation mode
- automatic maintenance of temperature
- optimum mode of work in the night time
- dehumidification of the air at high humidity
- control console
|
| | - mobile monoblock
- only air cooling mode
- control console
- area conditioning 24 sq. m
|
Similar Air conditioners
|
|
Brief specs
- cassette split-system
- heating and cooling air
- ventilation mode
- automatic maintenance of temperature
- optimum mode of work in the night time
- dehumidification of the air at high humidity
- control console
|
|
|
Brief specs
- ducted split-system
- pressure-70 PA
- heating and cooling air
- ventilation mode
- automatic maintenance of temperature
- optimum mode of work in the night time
- dehumidification of the air at high humidity
|
|
|
Brief specs
- wall split-system
- heating and cooling air
- ventilation mode
- automatic maintenance of temperature
- optimum mode of work in the night time
- dehumidification of the air at high humidity