General characteristics Type: duct split-system; The maximum length communications: 20 m; The main modes: cooling / heating; Max air flow: 33.33 cubic m/min; Static pressure: 70 PA; Power in cooling mode: 14000 W; Power in heating mode: 15200 W; Power consumption for heating: 5400 W; Power consumption cooling: 5300 W; Fresh air mode: yes; Additional modes: ventilation mode (without cooling and heating), auto mode, self-diagnostics of malfunctions; Dry mode: yes; Management Remote control: yes; Timer on/off: yes; Dimensions Internal block split-systems or mobile air conditioning (WxHxD): 142.5x26x66.3 cm; Outdoor unit split-systems and window air conditioner (WxHxD): 91.1x133.5x40 cm; Total Noise level (min/max): 40 dB 50 dB; Refrigerant type: R 410A; Phase: three-phase; The fine filters air: no; Adjusting the fan speed: yes; Other functions and features: the ability to adjust the air flow direction, the system against ice, the resume function settings; Minimum temperature for the operation of the air conditioner in a heating mode: -7°; Additional information: winter set Polo Nord - option;
|
|
Product photography
Quattroclima QV-I48DC / QN-I48UC pictures
More pictures
|
|
|
Popular today
| | - wall split-system
- only air cooling mode
- ventilation mode
- automatic maintenance of temperature
- optimum mode of work in the night time
- dehumidification of the air at high humidity
- control console
|
| | - wall split-system
- heating and cooling air
- ventilation mode
- automatic maintenance of temperature
- optimum mode of work in the night time
- dehumidification of the air at high humidity
- control console
|
| | - mobile monoblock
- only air cooling mode
- control console
- area conditioning 24 sq. m
|
Similar Air conditioners
|
|
Brief specs
- column split system
- heating and cooling air
- ventilation mode
- automatic maintenance of temperature
- the optimum mode of operation at night
- the dehumidification at high humidity
- operation via
|
|
|
Brief specs
- cassette split-system
- heating and cooling air
- ventilation mode
- automatic maintenance of temperature
- the optimum mode of operation at night
- the dehumidification at high humidity
- operation via
|
|
|
Brief specs
- floor-ceiling split system
- heating and cooling air
- ventilation mode
- automatic maintenance of temperature
- the optimum mode of operation at night
- the dehumidification at high humidity
- operation via
|
|