APC
Uninterruptible Power Supply
APC Smart-UPS VT 15kVA 400V, Start-Up 5X8, Internal Maintenance Bypass
Review ratings
|
APC Smart-UPS VT 15kVA 400V, Start-Up 5X8, Internal Maintenance Bypass
Rating: 0
Number of votes: 0
|
|
|
Workmanship
Relevant cost
Serviceability
|
|
Tech specifications and characteristics
Technical Characteristics Type: double conversion; Output power: 15,000 VA/12000 W; Output Waveform: sinusoid; The number of output power connectors: 3; Type of output power connectors: IEC 320 C13 (computer); Input/Output At the inlet: 3-phase power; Input voltage: 304 - 477 VVV; Input Frequency: 47 - 70 Hz; Output voltage (battery mode): ± 5%; Output frequency: 47 - 53 Hz; Management Interfaces: RS-232; Slot for optional interfaces: Yes; Support for SNMP: Yes; Functionality Information Display: LCD Screen; Audible alarm: Yes; Cold start: Yes; Manual By-pass: Yes; Automatic By-pass: Yes; Battery Connection of additional battery: Yes; Protection Protection from high-voltage pulses: Yes; Noise filtering: Yes; Additional Information Color: black; Dimensions (WxHxD): 352x823x906 mm; Weight: 134 kg; Features: 1 or 3-phase output voltage, No internal battery - uses external battery system;
|
|
Product photography
APC Smart-UPS VT 15kVA 400V, Start-Up 5X8, Internal Maintenance Bypass pictures
More pictures
|
|
|
Popular today
| | - Interactive UPS
- 1-phase input voltage
- Output power of 1500 VA
- Output connectors: 6
- Rackable
- Interfaces: RS-232
- 6 hours charging time
|
| | - UPS is a double conversion
- 3-phase input voltage
- Output power of 40,000 VA/32000 Tues
- Output: 1 (battery powered - 1)
- Interfaces: RS-232
- Output Waveform: Sine
|
| | - UPS is a double conversion
- 3-phase input voltage
- Power Output 20000 VA/16000 Tues
- 10 min at full load
- Output: 1 (battery powered - 1)
- Output Waveform: Sine
|
Similar Uninterruptible Power Supply
|
|
Brief specs
- UPS is a double conversion
- 3-phase input voltage
- Output power of 15,000 VA/12000 W
- 18.4 min at full load
- 46.5 min at half load
- Output: 2 (battery powered - 2)
- Interfaces: RS-232
|
|
|
Brief specs
- UPS is a double conversion
- 3-phase input voltage
- Output power of 15,000 VA/12000 W
- 18 min at full load
- 46 min at half load
- Output Connectors: 3
- Interfaces: USB, RS-232
|
|
|
Brief specs
- UPS is a double conversion
- 3-phase input voltage
- Output power of 15,000 VA/12000 W
- 27.4 min at full load
- 66.4 min at half load
- Output: 2 (battery powered - 2)
- Interfaces: RS-232
|
|