Tech specs and characteristics

Technical Characteristics
Type: double conversion;
Output power: 20000 VA/16000 Tues;
Time at full load: 5.5 min;
Time at half load: 18.3 min;
Output Waveform: sinusoid;
The number of output power connectors: 1;
Type of output power connectors: IEC 320 C13 (computer);
Efficiency: 95%;
Nonlinear distortion factor: 5%;
Input/Output
At the inlet: 3-phase power;
At the exit: 3-phase power;
Input voltage: 304 - 477 VVVV;
Input Frequency: 40 - 70 Hz;
Output frequency: 47 - 53 Hz;
Management
Interfaces: RS-232;
Support for SNMP: Yes;
Functionality
Information Display: LEDs;
Audible alarm: Yes;
Battery
Charging time: 5:00;
The possibility of replacing batteries: Yes;
Hot-swappable batteries: Yes;
Connection of additional battery: Yes;
Protection
Overload protection: Yes;
Protection from high-voltage pulses: Yes;
Noise filtering: Yes;
Short-circuit protection: Yes;
Fuse type: automatic;
Additional Information
Noise level: 54 dV;
Color: black;
Dimensions (WxHxD): 352x1490x838 mm;
Weight: 396.83 kg;
 
 
 
 
Product photography
APC Smart-UPS VT 20KVA 400V w/2 Batt Mod Exp to 2, Internal Maintenance Bypass pictures
More pictures
 
 
 
 
 

Popular today

 
ups Inform, ups Inform GUARD-S 1500 AP, Inform ups, Inform GUARD-S 1500 AP ups, uninterruptible power supply Inform, Inform uninterruptible power supply, uninterruptible power supply Inform GUARD-S 1500 AP, Inform GUARD-S 1500 AP specifications, Inform GUARD-S 1500 AP 
  • Interactive UPS
  • 1-phase input voltage
  • Output power of 1500 VA
  • Output connectors: 6
  • Rackable
  • Interfaces: RS-232
  • 6 hours charging time
 
 
ups Liebert, ups Liebert NXa 40 kVa, Liebert ups, Liebert NXa 40 kVa ups, uninterruptible power supply Liebert, Liebert uninterruptible power supply, uninterruptible power supply Liebert NXa 40 kVa, Liebert NXa 40 kVa specifications, Liebert NXa 40 kVa 
  • UPS is a double conversion
  • 3-phase input voltage
  • Output power of 40,000 VA/32000 Tues
  • Output: 1 (battery powered - 1)
  • Interfaces: RS-232
  • Output Waveform: Sine
 
 
ups MGE, ups MGE Comet S31 20 kVA, MGE ups, MGE Comet S31 20 kVA ups, uninterruptible power supply MGE, MGE uninterruptible power supply, uninterruptible power supply MGE Comet S31 20 kVA, MGE Comet S31 20 kVA specifications, MGE Comet S31 20 kVA 
  • UPS is a double conversion
  • 3-phase input voltage
  • Power Output 20000 VA/16000 Tues
  • 10 min at full load
  • Output: 1 (battery powered - 1)
  • Output Waveform: Sine
 
 
 

Similar Uninterruptible Power Supply

 
ups APC, ups APC Smart-UPS VT 20KVA 400V w/4 Batt Mod Exp to 4, Internal Maintenance Bypass, APC ups, APC Smart-UPS VT 20KVA 400V w/4 Batt Mod Exp to 4, Internal Maintenance Bypass ups, uninterruptible power supply APC, APC uninterruptible power supply, uninterruptible power supply APC Smart-UPS VT 20KVA 400V w/4 Batt Mod Exp to 4, Internal Maintenance Bypass, APC Smart-UPS VT 20KVA 400V w/4 Batt Mod Exp to 4, Internal Maintenance Bypass specifications, APC Smart-UPS VT 20KVA 400V w/4 Batt Mod Exp to 4, Internal Maintenance Bypass  
Brief specs
  • UPS is a double conversion
  • 3-phase input voltage
  • Power Output 20000 VA/16000 Tues
  • 18.3 min at full load
  • 46.5 min at half load
  • Output: 2 (battery powered - 2)
  • Interfaces: RS-232
 
 
ups APC, ups APC Smart-UPS VT 20kVA 400V w/2 Batt. Modules Exp. to 4, Start-Up 5X8, Internal Maintenance Bypass, APC ups, APC Smart-UPS VT 20kVA 400V w/2 Batt. Modules Exp. to 4, Start-Up 5X8, Internal Maintenance Bypass ups, uninterruptible power supply APC, APC uninterruptible power supply, uninterruptible power supply APC Smart-UPS VT 20kVA 400V w/2 Batt. Modules Exp. to 4, Start-Up 5X8, Internal Maintenance Bypass, APC Smart-UPS VT 20kVA 400V w/2 Batt. Modules Exp. to 4, Start-Up 5X8, Internal Maintenance Bypass specifications, APC Smart-UPS VT 20kVA 400V w/2 Batt. Modules Exp. to 4, Start-Up 5X8, Internal Maintenance Bypass  
Brief specs
  • UPS is a double conversion
  • 3-phase input voltage
  • Power Output 20000 VA/16000 Tues
  • 5.5 min at full load
  • 18.3 min at half load
  • Output: 2 (battery powered - 2)
  • Interfaces: RS-232
 
 
ups APC, ups APC Smart-UPS VT 20kVA 400V w/2 Batt. Modules, Start-Up 5X8, Internal Maintenance Bypass, APC ups, APC Smart-UPS VT 20kVA 400V w/2 Batt. Modules, Start-Up 5X8, Internal Maintenance Bypass ups, uninterruptible power supply APC, APC uninterruptible power supply, uninterruptible power supply APC Smart-UPS VT 20kVA 400V w/2 Batt. Modules, Start-Up 5X8, Internal Maintenance Bypass, APC Smart-UPS VT 20kVA 400V w/2 Batt. Modules, Start-Up 5X8, Internal Maintenance Bypass specifications, APC Smart-UPS VT 20kVA 400V w/2 Batt. Modules, Start-Up 5X8, Internal Maintenance Bypass  
Brief specs
  • UPS is a double conversion
  • 3-phase input voltage
  • Power Output 20000 VA/16000 Tues
  • 5.5 min at full load
  • 18.3 min at half load
  • Output: 2 (battery powered - 2)
  • Interfaces: RS-232
 
 
 
 
 
Payment methods Payment methods
Protezione massima Protezione massima