Delta ES
Uninterruptible Power Supply
Delta ES GA1000R
Estimated price for Delta ES GA1000R -
390.63€ - 613.68€
Review ratings
|
Delta ES GA1000R
Rating: 0
Number of votes: 0
|
|
|
Workmanship
Relevant cost
Serviceability
|
|
Technical specifications and features
Technical Characteristics Type: double conversion; Output power: 1000 VA/800 W; Time at full load: 4 min; Time at half load: 12 min; Output Waveform: sinusoid; The number of output power connectors: 5 (including battery-powered - 3); Type of output power connectors: IEC 320 C13 (computer); Rackable: Yes; Nonlinear distortion factor: 3%; Input/Output At the inlet: 1-phase power supply; At the exit: 1-phase power supply; Input voltage: 160 - 275VVV; Input Frequency: 45 - 65 Hz; Input power factor: 0.97; Output voltage (battery mode): ± 2%; Management Interfaces: USB, RS-232; Support for SNMP: Yes; Functionality Information Display: LEDs; Audible alarm: Yes; Cold start: Yes; Battery The possibility of replacing batteries: Yes; Connection of additional battery: Yes; Protection Overload protection: Yes; Protection from high-voltage pulses: Yes; Noise filtering: Yes; Short-circuit protection: Yes; Additional Information Noise level: 45 dV; Color: black; Dimensions (WxHxD): 440x89x335 mm; Height (in units): 2 U; Weight: 13 kg;
|
|
Product photography
Delta ES GA1000R pictures
More pictures
|
|
|
Popular today
| | - Interactive UPS
- 1-phase input voltage
- Output power of 1500 VA
- Output connectors: 6
- Rackable
- Interfaces: RS-232
- 6 hours charging time
|
| | - UPS is a double conversion
- 3-phase input voltage
- Output power of 40,000 VA/32000 Tues
- Output: 1 (battery powered - 1)
- Interfaces: RS-232
- Output Waveform: Sine
|
| | - UPS is a double conversion
- 3-phase input voltage
- Power Output 20000 VA/16000 Tues
- 10 min at full load
- Output: 1 (battery powered - 1)
- Output Waveform: Sine
|
Similar Uninterruptible Power Supply
|
|
Brief specs
- UPS is a double conversion
- 1-phase input voltage
- Output power 1000 VA/700 W
- 5 min at full load
- 14 min at half load
- Output Connectors: 4 (with a battery - 4)
- Interfaces: RS-232
|
|
|
Brief specs
- UPS is a double conversion
- 1-phase input voltage
- Output power 2000 VA/1400 W
- 5 min at full load
- 14 min at half load
- Output: 8 (battery powered - 8)
- Interfaces: RS-232
|
|
|
Brief specs
- UPS is a double conversion
- 1-phase input voltage
- Output power 3100 VA/2100 W
- 5 min at full load
- 14 min at half load
- Output: 8 (battery powered - 8)
- Interfaces: RS-232
|
|